TOPDRIVE VFD (EMC) ROZ1-K (AS) 1,8/3 kV

Diagram Variable Speed Drive pilots EMC SCREENED Power Cable
TOP DRIVE EMC VSD Power Cable Screened Braid
TOXFREE VSD EMC POWER CABLE BRAIDED SCREEN HALOGEN FREE

TOPDRIVE VFD (EMC) ROZ1-K (AS) 1,8/3 kV

3kV flexible EMC LSZH screened cable for Variable Frequency Drive motors (VFD cables)

TOPDRIVE VFD (EMC) ROZ1-K (AS) 1,8/3kV cable has been specially designed for Variable Frequency Drive Motors and installations where it is necessary to limit the effects of electromagnetic interference (EMI).

IEC 60502-1 / IEC 60092-353

DNV-GL / ABS / CE / RoHS / BUREAU VERITAS / LLOYD’S REGISTER

  • Industrial use / Variable Frequency Drive (VFD) / Electric fields resistant
  • Marine and Offshore
  • Pumps and Motors
  • Data Centers
  • Engineering

Fire performance

Flame non-propagation based on EN 60332-1 and IEC 60332-1.

Fire non-propagation based on EN 60332-3, IEC 60332-3 and EN 50399.

LSZH (Low Smoke Zero Halogen) based on EN 60754-1 and IEC 60754-1.

Low smoke emission based on EN 61034 and IEC 61034.: Light transmittance > 80%

Low corrosive gases emission based on EN 60754-2 and IEC 60754-2.

Reaction to fire CPR: Cca – s1a, d1, a1, according to EN 50575.

Mechanical performance

Minimum bending radius: x10 cable diameter.

Impact resistance: AG2 Medium severity.

Chemical performance

Chemical & Oil resistance: Acceptable.

UV Resistant according to EN 50618.

Water performance

Water resistance: AD5 Jets.

Conductor

Electrolytic annealed copper, class 5 (flexible), based on EN 60228 and IEC 60228.

Grounding Conductor

The ground conductor is divided into three conductors; the equivalent cross-section is approximately 50% of the section of the phase conductor.

Insulation

Cross-linked polyethylene (XLPE) according to IEC 60502-1 and type HF XLPE 90oC according to IEC 60092-351.

The standard identification of insulated conductors is the following:

3x + 3G grey + brown + black + yellow/green (3 G) (from 6 mm2 onwards)

Screen

Aluminium-polyester tape screen, helically placed over the insulated conductors. Over the tape there is a tinned copper braid screen. The tape and the braid act as a double screen to cut out all of the the electromagnetic interference.

The screen has a cover of 100% and its total section is approximately 10% of one of the conductors.

Outer sheath

Polyolefin type ST8 according to IEC 60502-1 and type SHF1 according to IEC 60092-360, black color.

Thermal performance

Maximum conductor temperature: 90ºC.

Maximum short-circuit temperature: 250ºC (max. 5 s).

Minimum service temperature: -40ºC (fixed and protected installations).

 

 

Enquire Now