LSZH SDI
IEC 60092-353
The Toxfree® Marine cable is halogen free and designed for shipbuilding, offshore and other marine purposes where LSZH cables are required.
In case of fire, it does not emit toxic or corrosive gases,
thereby protecting public health and avoiding any possible damage
to electronic equipment. For this reason, its use is recommended in
marine applications.
• Marine use.
• Public use
Conductor
Electrolytic annealed copper conductor, class 5 (flexible), according to
EN 60228 and IEC 60228.
Insulation
Cross-linked polyethylene (XLPE) insulation, type HF XLPE-90 ºC
according to IEC 60092-360.
The standard identification of insulated conductors according to HD 308
is the following:
1 x Natural
2 x Blue + Brown
3 G Blue + Brown + Green/Yellow
3 x Brown + Black + Grey
3 x+1 x Brown + Black + Grey + Blue (reduced cross-section)
4 G Brown + Black + Grey + Green/Yellow
4 x Brown + Black + Grey + Blue
5 G Brown + Black + Grey + Blue + Green/Yellow
Outer sheath
Low Smoke Halogen Free (LSHF) polyolefin outer sheath. Black
colour
CHARACTERISTICS
Electrical performance
Low voltage: 0,6/1 kV
Thermal performance
Maximum service temperature: 90º
C.
Maximum short-circuit temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC (fixed and protected
installations).
Minimum installation and handling temperature: 0ºC (on cable surface).
Fire performance
Flame non-propagation according to EN 60332-1 / IEC 60332-1.
Fire non-propagation according to EN 60332-3-24 / IEC 60332-3-24 and
EN 50399.
Reaction to fire CPR: B2ca-s1a,d1,a1 according to EN 50575.
LSHF (Low Smoke Halogen Free) according to EN 60754-1 / IEC 60754-1.
Low smoke emission according to EN 61034 / IEC 61034:
Light transmittance > 80%.
Low corrosive gases emission according to EN 60754-2 / IEC 60754-2.
Mechanical performance
Minimum bending radius: 5x cable diameter.
Impact resistance: AG2 Medium severity.
Environmental performance
Chemical & Oil resistance: acceptable.
UV Resistant according to EN 50618.
Water resistance: AD5 Jets.
Installation conditions
Open Air.
Buried.
In conduit.